Work orders
Walk-in Freezer Not Cooling
WO-2024-0002 · Emergency
Labor
$675
Parts
$94.20
Total cost
$769.20
Hours (est. / actual)
3 / 3.75
Job
- Work order number
- WO-2024-0002
- Work type
- Emergency
- Priority
- Critical
- Status
- Completed
- Description
- Emergency call for walk-in freezer failure at Brooklyn restaurant.
- Problem
- Freezer temperature rose to 28F; compressor not running.
- Work performed
- Diagnosed failed start capacitor and contactor; replaced both and verified pull-down to -5F.
- Parts used
- Start capacitor 88-108 MFDContactor 2-pole 40A
- Customer notes
- After-hours rate applied. Product moved to reefer truck temporarily.
Schedule
- Scheduled start
- Mar 7, 2024 · 11:30 PM
- Scheduled end
- Mar 8, 2024 · 2:30 AM
- Actual start
- Mar 7, 2024 · 11:20 PM
- Actual end
- Mar 8, 2024 · 3:05 AM
Customer1
Work order —RequestedByCustomer→ Customer
Site1
Work order —PerformedAtSite→ Site
Technician1
Work order —AssignedToTechnician→ Technician
Asset serviced1
Work order —ServicesAsset→ Asset
Covering agreement1
Work order —FallsUnderAgreement→ Service agreement
Invoices1
Work order —BilledOnInvoice→ Invoice paired with BillsWorkOrder